Multi-vector MPC
as the basis for
planning and control.
Evana is the techno-economic optimisation engine: for design and sizing during pre-engineering, and for daily control through Flow.
Every decision
looks ahead.
Conventional control responds to what is happening now: if the buffer is cold, the heat pump switches on. Model Predictive Control calculates ahead first.
Using a model of the installation and forecasts of demand, weather and prices, MPC calculates the best operating strategy for the coming hours. Only the first step of that plan is carried out.
After fifteen minutes, we measure again, update the forecasts and recalculate the plan. Control is adjusted whenever actual conditions differ from expectations.
A model starts
with your installation.
Measurements reveal asset conditions and actual energy demand. The system model describes how generation, conversion, storage and consumption interact.
Physics and data,
the best of
both worlds.
Our models combine physical knowledge of the installation with data-driven calibration.
Physics describes how heat, electricity, conversion and storage interact. Measurements help align the model with the behaviour of the actual installation.
This combines explainable models with a practical basis for planning and real-time control — from a shared heat source to industrial utilities.

Every energy vector
in one optimisation.
Multi-vector means managing electricity, heating, cooling, hydrogen and storage together.
A heat pump is both an electrical load and a heat source; a buffer shifts both over time. Optimising operation at system level requires considering them together.
Steam, compressed air
and more.
The engine is vector-agnostic: additional energy vectors and processes can be incorporated as modules in the system model. We align the available and required modules with the industrial or residential application.
Safe architecture
in layers.
Flow plans 24 hours ahead and recalculates every fifteen minutes. Edge controllers connect the field equipment; SYNAPSE provides the central platform.
A new plan uses the latest measurements and forecasts. Local controllers remain responsible for execution.
Flow / SYNAPSE
Bringing together data, forecasts and system models for planning and operational optimisation.
Edge controllers & interfaces
Telemetry and validation; exchanging measurements and agreed commands with assets and local control systems.
PLC / BMS / battery controller
Fast grid control, process control, interlocks, protection and fallback remain local.
What could MPC do for your installation?
We would be happy to review your system diagram, measurement profiles and grid limits together.