References / from challenge to an evidence-based approach

Complex energy challenges.
Practical experience.

From a research campus to a shared residential development. Hylife brings technology, energy flows and use together — through system studies, connected installations and completed demonstrations.

01 / Multi-vector energy campus

The Green Village · TU Delft

TU Delft Campus · Delft

From an energy hub for one home to an integrated campus.

At The Green Village, the field lab on the TU Delft Campus, sustainable innovations are tested in a real built environment. The existing 24/7 lab combines local solar energy with battery and hydrogen storage. The next question: how can this concept be scaled to a site with multiple buildings and charging points as the available grid connection, energy use and objectives change?

Hylife brought consumption profiles, PV generation and charging behaviour together in a dynamic optimisation model. This enabled a comparison of combinations of grid capacity, solar panels, battery storage and the hydrogen chain. The study examined how the desired balance between economic performance, CO₂ impact and grid use affects the required components and their interactions.

The comparison shows that no single storage technology is necessarily the best solution under all conditions. The combination of usage profiles, grid limits and the selected objective determines the appropriate configuration. Hylife thus provided an evidence-based foundation for further development of the energy hub. The completed study focused on electrical energy flows and the associated storage chains; further thermal integration is a next step in the campus development.

  • PV, batteries and hydrogen in one system model
  • Scaling from a home to an entire site
  • Configurations assessed against grid use and CO₂ objectives
The existing 24/7 Energy Hub at The Green Village, with solar panels and hydrogen storage
The Green Village · photograph by Robert Kroonen ↗
02 / District heating with Power-to-Heat

Goeree-Overflakkee

Goeree-Overflakkee · Middelharnis and Sommelsdijk

Connecting local electricity with the heat demand of communities.

On Goeree-Overflakkee, local renewable electricity generation and decarbonisation of the built environment come together. Power-to-Heat offers a potential link: converting electricity into heat, storing it and supplying it through a district heating network. The challenge is to design heat production and storage around building demand, changing electricity conditions and available grid capacity.

Together with Innoforte, Hylife carried out a pilot study for the municipality. Its contribution included validating assumptions and dynamically simulating heat sources, buffers, the grid connection and control. Different configurations and operating strategies were compared, including heat pumps, electric boilers, thermal storage and wind energy supplied through a PPA. This revealed how technical choices interact with electricity procurement and grid access arrangements.

The next step focuses on further substantiating a potential district heating network for Middelharnis and Sommelsdijk. Hylife supports the techno-economic development of generation assets, control strategies and system sizing. This advisory phase supports further decisions on the design and integration of the shared heat supply.

  • Dynamic simulation of heat production and storage
  • Linking heat demand, PPAs and grid capacity
  • Evidence to support further area development
Street view of Middelharnis, one of the communities studied
Middelharnis · Klimaatkrachtig GO / municipality of Goeree-Overflakkee ↗
03 / Power-to-Heat and shared heat supply

Schouwen-Duiveland

Brouwershaven, Bruinisse, Renesse and Zierikzee

Exploring heat supply through both buildings and the electricity grid.

For Schouwen-Duiveland, the study examined how Power-to-Heat and thermal storage could contribute to future shared energy systems. In Brouwershaven, Bruinisse, Renesse and Zierikzee, the building stock and heat demand were assessed alongside opportunities for district heating. The challenge goes beyond selecting a heat source: grid congestion, integration into existing homes and the flexibility of heat production also determine feasibility.

As part of the joint Warmteverduurzaamd exploration, Hylife contributes expertise in system simulation and optimisation. Different control strategies were compared, from heat production that directly follows demand to charging thermal buffers in advance. Capacity-limited grid arrangements combined with wind energy through a PPA were also explored. This shows how storage can help align production and consumption over time.

The study connects spatial analysis with the behaviour of the energy system throughout the year. This provides a substantive basis for selecting promising heat clusters and next steps. Zierikzee emerged as a location for further investigation. Further development can connect the technical configuration, local integration and collaboration with local parties in a concrete development programme.

  • Four communities in one exploration
  • Thermal buffers and flexible grid consumption
  • From area analysis to more detailed system choices
Map of the study area around Zierikzee from the Power-to-Heat exploration
Warmteverduurzaamd · study area from the project presentation
04 / Multi-vector shared energy supply under grid congestion

Poort van Hoorn

Hoorn, the Netherlands

Housing and energy supply within the same grid limit.

Within the Poort van Hoorn development, Hylife is investigating how a new residential building with apartments, commercial space and shared facilities can be supplied with energy in an area affected by grid congestion. The challenge lies in the combined demand for household electricity, heating, domestic hot water and cooling. An energy concept therefore needs to be assessed against both annual consumption and the power the building requires during busy periods.

For building 3C, Hylife compared individual and shared all-electric solutions. Dynamic simulations revealed the interactions between heat pumps, PV, thermal buffers, batteries and the different consumers. Both installation sizing and operation were investigated. The required plant space and implications for the wider development were also considered.

The study shows how shared facilities, coordinated storage and control can reduce required grid capacity, and which design conditions are needed. It gives the developer and advisers an evidence-based comparison of the options, including remaining constraints. The result provides a foundation for further design and investment decisions within the wider development.

  • Individual and shared energy concepts compared on the same basis
  • Heating, cooling, electricity, PV and storage dynamically connected
  • Grid capacity and spatial integration as joint design constraints
Urban planning study visualisation of Poort van Hoorn, with residential buildings beside the railway
Poort van Hoorn · urban planning study visualisation
05 / Large-scale multi-vector energy campus

VITO

Mol, Belgium

An energy strategy that grows with a research campus.

VITO’s research campus in Mol combines laboratories, offices and technical installations with diverse energy needs. The phased development of new buildings requires an energy strategy that assesses existing infrastructure and future expansion together. Heating, cooling and electricity must match both the functions of the buildings and the long-term development of the site.

For the energy master plan update, Hylife supports SVR-ARCHITECTS in collaboration with Ingenium. The assignment focuses on developing and calculating different energy scenarios, treating demand profiles, local PV generation, contractual conditions and the sizing of key energy assets as interconnected elements. Sensitivity analyses show how choices respond to changing assumptions. An ORC model and an exploratory hydrogen scenario are also included in the study design.

The campus is therefore approached as a single energy system in which building development, conversion, generation and infrastructure influence one another. Hylife substantiates possible development directions through system models and scenario comparisons. The collaboration connects the campus’s architectural and building-services development with the sizing and operation of energy assets.

  • Long-term development of heating, cooling and electricity
  • Energy asset sizing and operation for each scenario
  • Collaboration with SVR-ARCHITECTS and Ingenium
The EARTH research building on the VITO campus in Mol
VITO EARTH, Mol · image via SVR-ARCHITECTS ↗
06 / Multi-vector shared energy supply

Genderhof Eindhoven

Genderbeemd, Eindhoven, the Netherlands

Assessing electrical capacity for a new residential development.

Genderhof is a redevelopment in Eindhoven where existing apartments are being replaced by a larger residential development with shared heating and cooling. Grid congestion makes available electrical capacity a key constraint. Alongside household consumption, lifts, communal facilities and the energy centre also require power. The question is how to assess these users within a single, coherent energy budget.

Hylife brought the electrical demand of homes, shared facilities and the thermal system together in a dynamic analysis. The exploration compares different levels of control and examines the effects of thermal buffers, heat pump sizing and a shared battery. It accounts for the timing of demand and the influence of temperatures on heat pump performance.

The results show which measures reduce peak demand and where additional interventions remain necessary. That last point is essential: the combination of control and storage studied proved insufficient on its own to stay within the available capacity. The study therefore guides further investigation into the installation design and additional measures. This reference shows how an integrated energy analysis can support design decisions without overstating the capabilities of smart control.

  • Homes, shared facilities and the energy centre in one analysis
  • Heat pumps, thermal buffers and electrical storage compared
  • Remaining capacity constraints explicitly identified
Design visualisation of the new residential buildings and green public space at Genderhof Eindhoven
Genderhof, Eindhoven · design visualisation by FAAM architects ↗
07 / Connected heat interface units, devices and services

Giacomini · GiacoPortal

Giacomini · shared buildings and homes

From heat interface unit to building: one installation, the right information.

Shared heating and cooling systems bring together residents’ comfort, technical maintenance and operations. Giacomini connects these perspectives in GiacoPortal. A heat interface unit does not operate in isolation: booster heat pumps, thermostats and energy meters also form part of the installation that provides comfort to a home. The challenge is to make the relationships between these devices useful to the people who operate and maintain the installation.

Hylife provides the connection between field equipment and the central data platform. The edge controller collects device data and connects the installation to SYNAPSE. GiacoPortal gives this information a partner-specific application, with access and functions matched to each user’s role.

The supplied screens show the different levels of detail. An ESCO can view building status, hydraulic relationships and reports. A service engineer can move from a system schematic to device measurements, permitted settings and communication validation during commissioning. This creates a single information chain from the connected device to daily service, with measurements and actions in their technical context.

  • Edge controllers connect heat interface units and associated devices
  • SYNAPSE as the data foundation for the partner-specific portal
  • Connected building management, service diagnostics and commissioning
GiacoPortal — ESCO · Building overview; supplied screen with fictional names Eikenhorst and Hof van Sering
GiacoPortal · supplied screenshot, ESCO role
08 / Multi-vector energy hub

InnovaHub

Havenstadt · Stad aan ’t Haringvliet

Generation, storage and comfort connected in a small neighbourhood.

In Havenstadt, a residential development in Stad aan ’t Haringvliet, Hylife developed and built InnovaHub. This local energy hub supplies heating and cooling to a small neighbourhood and brings together electricity, thermal energy and hydrogen. The central question is how locally generated solar energy can better meet household needs, including when generation and demand occur at different times.

The installation combines solar panels, heat pumps, heating and cooling buffers, battery storage and a hydrogen chain with electrolysis, storage and reconversion. The components are controlled together using forecasts of weather, energy demand and conditions on the electricity grid. Heating and cooling reach the homes through the shared network and heat interface units.

In this demonstration project, Hylife brought together design, simulation, automation and practical experience. The installation was first assembled and tested, then relocated to the neighbourhood. The homes were connected and handed over in 2024; monitoring and service continue from the Experience Center. InnovaHub is therefore a practical learning environment for integrated energy systems, including collaboration with construction partners, suppliers, residents and competent authorities.

  • Electricity, heating, cooling and hydrogen
  • From design and testing to neighbourhood supply
  • Monitoring and practical experience from the Experience Center
The completed Havenstadt neighbourhood with solar panels and InnovaHub in Stad aan ’t Haringvliet
Havenstadt, Stad aan ’t Haringvliet · Hylife project photograph
From your question to a practical approach

What connections does
your energy supply need?

Discuss your buildings, processes and constraints. Together, we identify the analysis or technical connection that supports the next step.

Discuss your challenge ↗